Subject: [sv-bc] Proposal for SV-BC-100
From: Dave Rich (David.Rich@synopsys.com)
Date: Mon Dec 08 2003 - 00:05:42 PST
The always_ff block
imposes the restriction that only one event control is allowed.
Software tools can perform additional checks to warn if the behavior
within an always_ff procedure does not represent sequential
logic.
The always_ff block imposes the restrictions that it contains at least one event control and no blocking timing controls. Variables on the left-hand side of assignments within an always_ff procedure, including variables from the contents of a called function, shall not be written to by any other process. Software tools can perform additional checks to warn if the behavior within an always_ff procedure does not represent sequential logic.
-- -- David.Rich@Synopsys.com Technical Marketing Consultant http://www.SystemVerilog.org tele: 650-584-4026 cell: 510-589-2625