RE: [sv-bc] Are modport port directions enforced?

From: Bresticker, Shalom <shalom.bresticker_at_.....>
Date: Mon Feb 26 2007 - 13:36:43 PST
No,no,no! It is never a directional problem to read from an output!
(The question of capacitance load on the output driver is a separate
question.)
See my bugnote to 1573.

Think of the physical reality. The fact that a gate has multiple fanout,
one inside the module and one outside, does not turn that wire into an
inout. Only when it is driven from outside to inside.

> it should be an error to ...
> read from a modport port of direction output.

Shalom

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Mon Feb 26 13:37:41 2007