[sv-bc] Confusion on setting parameters in configurations

From: Surya Pratik Saha <spsaha_at_.....>
Date: Tue Jan 13 2009 - 05:44:43 PST
Hi,
I did not get any response on this mail. So I am resending it again.

In the 'Setting parameters in configurations' chapter there are following restrictions described. My confusions described in blue text.

— Parameters identifiers shall be resolved starting in the parent scope of the instance. If a hierarchical identifier is used, it must be the only term in the expression, e.g., a.b.c + 7 is invalid.
"Is the referred "hierarchical identifier" referring parameter override expression of that parameter identifier? If not then what it is referring to? Please give some example."
— Parameter identifiers that bind into the parent of the configured instance shall be identifiers that are legal in a bind statement.
"What can be an illegal parameter identifier in bind statement? Please give some example."
— Hierarchical references cannot include scopes of generate or array of instances.
"Is the "hierarchical references" referring parameter override expression or instance hierarchical reference? Please give some example."
-- 
Regards
Surya

--