RE: [sv-bc] changing the lifetime of begin end block

From: Bresticker, Shalom <shalom.bresticker@intel.com>
Date: Thu Feb 11 2010 - 22:53:48 PST

We answered this.

6.21 is the subclause that defines this normatively.

23.2.1 just contains an informative high-level description of the module header. This sentence can be changed since it creates a confusion in at least one reader.

Shalom

> -----Original Message-----
> From: Daniel Mlynek [mailto:daniel.mlynek@aldec.com.pl]
> Sent: Friday, February 12, 2010 8:01 AM
> To: Bresticker, Shalom; jwill@BasicISP.net; sv-bc@eda.org
> Subject: RE: [sv-bc] changing the lifetime of begin end block
>
> I think that in whole disciussion you've forget about my
> orginal doubt.
> Which is : is automatic lifetime defined for module should change the
> lifetime of the variable defined in begin...end blocks in
> always/initial
> processes?
> LRM 1800-2009 says: "The module header defines the following: - The
> default lifetime (static or automatic) of subroutines defined
> within the
> module"
> If this lifetime from module header should change also
> lifetime of variables
> from begin...end blocks then above sentence should be
> changed. If not then
> it is ok.
---------------------------------------------------------------------
Intel Israel (74) Limited

This e-mail and any attachments may contain confidential material for
the sole use of the intended recipient(s). Any review or distribution
by others is strictly prohibited. If you are not the intended
recipient, please contact the sender and delete all copies.

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Thu Feb 11 22:54:08 2010

This archive was generated by hypermail 2.1.8 : Thu Feb 11 2010 - 22:54:15 PST